Nivelco Instruments – Refrigeration and Cooling

 

Nivelco Instruments Refrigeration Cooling Process

Nivelco Process Instruments for Refrigeration and Cooling Process

Nivelco and Aqua Technology Group can provide all you instrumentation needs for refrigeration, ammonia cooling and related processes.

The Nivelco Refrigeration and Cooling process diagram below illustrates a cooling technologic process commonly used in food, chemical and pharmaceutical industrial plants.

On the process diagram can be seen the cooling compressor applying ammonia, the circulating pump system and the liquid separator tank with the proposed Nivelco devices.

Nivelco Product Used

Instrumentation of the compressor:

  • The measurement of the pressure on the suction and pressure side is accomplished by NIPRESS DRC-3xxx type pressure transmitter
  • The measurement of the temperature is completed by THERMOCONT TTJ-Sxxx temperature transmitters
  • The suction side pressure transmitter performs the power control or the compressor, while the pressure side transmitter controls the condenser

Instrumentation of the liquid-separator:

  • The continuous level measurement is executed by NIVOCAP CTR-2xxx type capacitive level transmitter
  • This device controls the feeding valve applying me UNICONT PMM-311 type controller
  • The upper and lower failsafe switching is executed by NIVOMAG MKA-210 type level switches,
  • As high level is reached, the compressor shuts off, while at low level the ammonium pump is stopped.

Instrumentation of the liquid tank:

  • The instruments and procedure is similar to the separator but a NIVOTRACK MRC-5xxx type level transmitter is recommended due to the high pressure (16 bar)

Instrumentation of the cooling water:

  • A continuous level measurement is accomplished with EchoTREK SGA-3xxx type ultrasonic level transmitter, the level in the tank is kept constant by the help of a UNICONT PMM-311 type controller by actuating a supplementary water valve
  • The continuous conductance measurement is executed with an ANACONT LGK-2xxx type device,
  • The conductivity or cooling water is permanently increasing due to the evaporation in the condenser, so at a predetermined value, the PMM-311 controller opens the emptying as well as the supplementary valve
  • The low and high failsafe NIVOSWITCH RFM-401 type switches protect the pump and issue the alarm signals.

Instrumentation of the condenser:

  • The level control of the water tank under the condenser is accomplished by a NIVOCONT KKH-222-5 type level switch.

 

Nivelco Instruments for Wastewater Treatment

Nivelco Process Instruments for Wastewater Treatment.

Nivelco and Aqua Technology Group can provide all your instrumentation and control needs for collection systems, liftstations and pumps, package plants and wastewater treatment plant. This diagram of the wastewater treatment process details two separate sections: wastewater treatment processes and slurry treatment processes.

COLLECTION SYSTEM / LIFTSTATIONS / SUMPS / PITS

The sewage is collected in lifstations, underground sumps or pits, also known as wetwells, and is pumped to the sewage treatment plant.

Measurement and control tasks:
Reliable level measurement is necessary to provide pump start and stop signals with fail safe switch-off points to avoid dry running.

RECOMMENDED INSTRUMENTS

The  EasyTREK SP type non-contact ultrasonic level transmitter models with IP68 ingress protection is Nivelco’s recommendation for this measurement task.

Another popular choice for liftstations or deep sumps is the flush mounted  NIVOPRESS NC  type
hydrostatic borehole transmitter or the NIVOPRESS NP  series with recessed membrane equipped with a sewage adaptor working on the principal of the diving bell.

Nivelco NIVOPRESS N NIVOPRESS D transmitter

A  PLC  or our  MultiCONT  process controller unit is ideal to process the analogue 4…20 mA signals and to control the switching points. For fail-safe protection, the robust NIVOFLOAT NWP float level switches are recommended.

Nivelco Nivofloat and Nivocont

WASTEWATER TREATMENT PLANT

The sewage pumped in from the network contains a lot of organic and non-organic materials in suspended form as well as in solution. This pollution has to be removed. The particles are filtered with a mechanical screen. The dissolved pollution can be reduced by adding coagulant materials. The reduced slurry is then separated from the water in the sedimentation tank.
The purified sewage can be streamed to any natural water after chemical inspection and yield measurement.

RECOMMENDED INSTRUMENTS

  • Ultrasonic level transmitters for level measurement (2-wire integrated  (blind) or compact versions), EchoTREK or EasyTREK
  • For the control of the mechanical screen a differential system with 2 ultrasonic level transmitters is recommended
  • The  AnaCONT  range of analytical measurement devices is ideal for the chemical analysis of the cleaned water
  • Open channel flow metering can be done using our  Parshall flume, and  EasyTREK level transmitter.
  • Nivelco EasyTREK Echo-TREK ultrasonic transducers
  • For the calculation and data logging a MULTICONT PEW controller can be used.
  • High and low level switching will be performedwith NIVOSWITCH vibrating fork sensors

 

WASTEWATER TREATMENT PLANT,SLURRY TREATMENT PROCESS

The slurry separated in the sedimentation tank istransferred to the digester tank. The emitted biogas is stored in a biogas tank and then fed to a biogas generator. The biogas section of the plant is classified as a hazardous environment. The slurry retained in the digester is transported from the plant after dewatering (dehydration)

RECOMMENDED INSTRUMENTS

  • ATEX certified ultrasonic level transmitters(EchoTREK  or  EasyTREK) or ATEX certified guided microwave level transmitter (Micro-TREK) can be used for level measurement.
  • Nivelco’s choice for measuring the temperature of biogas is the ATEX certified temperature transmitter THERMOCONT TTJ Ex.
  • Nivelco recommends an ATEX certified pressure transmitter for measuring the biogas pressure the NIVOPRESS DT Ex

Nivelco Water Wastewater Instrument Selection

Nivelco Field Instruments In Measurement Systems

Nivelco Instruments for Potable Water Production

Nivelco Instruments for Potable Water

Nivelco Process Instruments for Potable Water Production.

Nivelco and Aqua Technology Group can provide all your instrumentation needs for production wells, purification, treatment, and distribution system.

PRODUCTION WELLS

The production wells are drilled in ground layers rich in water, the pumps are lowered into the wells to pump the raw water to the central water treatment facilities.

  • Measuring tasks:
  • Continuous level measurement of the well
  • Temperature measurement of the water
  • Hydrostatic pressure (water level) of the production well
  • Flow of the produced water
  • Dry-run protection of the pumps

RECOMMENDED INSTRUMENTS

  • Hydrostatic level transmitters that combine level and temperature measurement: the NIVOPRESS N transmitter family.
  • Piezoresistive pressure transmitters: NIVOPRESS NZK types
  • Water input measurement: ISOMAG electro-magnetic flow meters

WATER TREATMENT PLANT

The raw water pumped from the production wells contains different organic and inorganic materials. These materials have to be removed from the water. Removal is done either by mechanical filters or by adding coagulant materials to the water to help precipitate the contaminating materials. The resulting slurry is separated in settling tanks. The clean water is often passed through sand or other final filtration stages.

RECOMMENDED INSTRUMENTS

WATER DISTRIBUTION SYSTEM

To move water out to the distribution system and to the customers, the pressure in the system has to be increased. This is done by booster pumps, water towers or air charged pressure vessels with compressed-air pumps.

RECOMMENDED INSTRUMENTS

Nivelco Field Instruments In Measurement Systems

Nivelco

Aqua Technology Group is proud to offer quality Nivelco process instruments.

NIVELCO Product MATRIX

LEVEL TRANSMITTERS
Non-contact Microwave PiloTREK
Guided Microwave MicroTREK
Ultrasonic Compact EchoTREK for liquids
EchoTREK for solids
Ultrasonic Integrated EasyTREK for liquids
EasyTREK for solids
Capacitive NIVOCAP
Magnetostrictive NIVOTRACK
Hydrostatic pressure NIVOPRESS D
NIVOPRESS N – borehole transmitter
LEVEL SWITCHES
Float NIVOFLOAT
Conductive NIVOCONT K
Magnetic Coupling NIVOMAG
Magnetic Tracking NIVOPOINT
Vibrating NIVOCONT R – vibrating rod
NIVOSWITCH – vibrating fork
Rotary Paddle NIVOROTA
LIQUID ANALYSIS
pH and ORP transmitters AnaCONT LE
Conductivity transmitter AnaCONT LEK / LCK
DISPLAYS AND CONTROLLERS
Loop indicator UNICONT PDF
Controller/Indicator UNICONT PMM
UNICONT PMG
Controller / Programmer / Indicator MULTICONT
PRESSURE
Pressure transmitter NIPRESS
Hydrostatic pressure NIVOPRESS D
TEMPERATURE
Thermometers THERMOCONT TT
Temperature sensor THERMOCONT TN
SENSORS AND ACCESSORIES
Current Controlled Switch UNICONT PKK
Ultrasonic Proximity Sensor MICROSONAR
Accesory HART MODEM
Universal Interface Module UNICONT PJK-100
Power supply NIPOWER
SOFTWARE
Process visualization software NIVISION
OLDER PRODUCTS
Ultrasonic Two-part System NIVOSONAR